oil industry water tube boiler

oil industry water tube boiler

What does the Fangkuai industry water tube boiler tell you about instrument activity analysis? What is the effect of instrument activity analysis? The operation of the boiler is reflected by the instructions of various instruments. According to the indicator data of the instrument and its changing trend, it is the analysis of the instrument activity to analyze whether the boiler's working condition is normal or not. The normal operating parameters of the boiler are measured by various thermal monitoring instruments in various parts. The vehicle data include pressure, temperature, flow rate, water level, current, etc. In normal operation, by monitoring the operation of these parameters, we can analyze and judge the operation condition of the passageway, and when the accident occurs, we can also pass the Abnormal data changes to analyze and judge the location and nature of the accident, this timely handling of the accident to create conditions. The surge of induced fan is due to the excessive differential pressure in the inlet and outlet of its static blade. The differential pressure of the inlet and outlet of the stator blade is influenced by the resistance of the pipe, and the same induced fan is more prone to surge when the resistance of the static blade opening pipe is large. The static blade opening of the induced fan produces the corresponding wind pressure and flow rate. When the pressure and flow rate produced by the fan are greater than or equal to the resistance of the flue gas pipe, the fan can work stably without surging. When the resistance of the pipe increases, the pressure flow at the outlet of the fan can not overcome the resistance of the pipeline system. The force reverses the current. When the pipe resistance is reduced to the fan outlet pressure, the flue gas flows downstream. The smoke flows back and forth in such a way that it is surging. Therefore, when the resistance of wind-smoke pipe is large, it is more prone to surge when the output force is not enough. The influence of starting and stopping pulverized coal production system on boiler combustion condition is analyzed. As a result of the three-time air belt powder, the furnace fuel quantity increases / decreases, and the oxygen content increases / decreases relatively when the pulverized coal production system is started / stopped. When the pulverized coal making system starts for a long time, the boiler flame length is long, the furnace fire filling degree is good, and vice versa; under low load, the multiple pulverizing system operates or completely stops the pulverizing system, especially to prevent the flame from suddenly extinguishing. Once What is the cause of duct clogging? How to prevent it? Reasons: 1) the burner is blocked by coke or the inlet of the burner is partly blocked by small oil gun. 2) too many impurities in pulverized coal, too high speed of pulverized coal feeder, too heavy pulverized coal and too low primary wind speed. 3) the speed of powder feeder is too high. Too much powder to blow away in time. 4) the wind pressure is too low once (the wind door is not open or the opening degree is too small), do not take away powder. Preventive measures: 1) according to the speed of the powder feeder and the load of the unit, the corresponding primary air pressure should be adjusted in time, the speed of the powder feeder shall not be greater than 700 rpm, the primary wind speed of each unit shall be kept at 25 ~ 30 m / s, and the mixing temperature of the primary air and powder shall be controlled at 180. At ~ 250 ℃, the primary wind pressure depends on the load and coal quality, and the range of variation is in the range of 2.5~3.8kPa.2) it is found that the primary wind speed is too low. When the primary air temperature is lower than the normal value, the primary air velocity and the primary air temperature corresponding to the speed of the powder feeder should be reduced in time. 3) the boiler oil tank stop powder feeder should fully blow the tube. Blow away the powder from the powder tube. 4) scorch or clog the fire nozzle and try to get rid of it. Which causes the induced fan vibration? 1) motor bearing oil shortage, resulting in bearing wear and vibration; 2) coupling installation center is not good; 3) induced fan stall surge; 4) induced fan ground angle bolt Loose; 5) blade ash or wear, out of balance.

Boiler ignition How hard? Preparatory work must be done in place! We see, out of sight, the industry water tube boiler provides a steady stream of power, supporting all aspects of our daily life and industrial production needs, making great contributions to urban development and social progress of civilization. When you buy the right to their own businesses boiler equipment, how to properly operate the boiler operation becomes very important. In order to ensure the normal operation of the boiler, before ignition must be strictly checked and fully prepared; to do the following seven steps before you can begin to start the ignition. A, check and adjust the water level in the boiler water level adjusting on the display of digital boiler water gauge, when the boiler water level below the normal level required, when the water level above the normal water level will have to open the drain valve timing drainage, the water level reaches a predetermined. The water level should not exceed the normal water line when the boiler for the first time (cold oven) Sheung Shui. This is because the boiler ignition, water boiler thermal expansion is likely to exceed safe water line. Once this happens, the water level should be adjusted by sewage. If the water table level and table column is connected, to check whether the valve opening meter column connected tube. If the water table glass contamination, poor resolution, and must be cleaned or replaced with new equipment. Second, the former boiler blowdown test run, the test should be done on the sewage discharge valve, the valve is fully closed after confirming good, be careful not to have leakage. Third, check the pressure gauge to check the position of the pressure gauge; boiler no pressure gauge pointer should be limited stop limiting, the staple of the staple, the pointer value from zero gauge should not exceed the predetermined allowable error. When the gauge does not meet the requirements should be promptly replaced. Note that the header gauge cock in the open position. Fourth, check the water supply system of water storage tank to check the adequacy of whether the water supply piping and valves open. Manual and automatic water supply for the test, to confirm its good performance, the correct action. Fifth, check the furnace flue damper open ventilation will begin ventilation, have induced draft fan should start induced draft fan for ventilation. If the natural ventilation flue long and winding, ventilation time is generally less than 10 minutes; the wind if mechanical ventilation, generally less than 5 minutes. Six, ventilation equipment inspection and inspection of all fuel grate transmission section condition, to remain intact, normal rotation job. Reserves the liquid fuel tank should be checked, the gas fuel check gas reserves, and while confirming the oil pressure is normal. Fuel lines, filters, fuel pumps, the valve opening and closing the pipeline should be checked to ensure that no exception. Start oil heater, oil maintaining an appropriate temperature. Check the opening and closing of the control valve to meet the requirements. Confirm alarms work properly. Check flame monitor light-receiving surface and protects the lens is clear and transparent. Restrict the chain system is normal. Seven check automatic control device close the power switch, the power indicator confirmed by the control panel is turned on. Check the medium (air) and the fuel line for each valve opening and closing state of the pipeline, which confirmed that no leakage, no abnormal. Check the water level detection device, the specified maximum and minimum water level at the limit, the ability to correctly stop the pump and start pumping. Check the opening and closing of the control valve to meet the requirements. Low water level alarm can confirm correct operation. Check flame monitor light-receiving surface and protects the lens is clear and transparent

What are the precautions in the loading and installation of gas-fired steam industry water tube boilers?

Gas-fired steam boilers are a very wide range of special equipments, widely used in food, chemical, paper, textile, construction and other industries. In the process of loading and installing a gas steam boiler, some problems must be paid attention, otherwise it may cause a certain degree of economic loss.

1. Pay attention to the following matters during the loading and unloading and handling of gas-fired boilers: the lifting capacity of the lifting equipment should match the weight of the lifting boiler. The lifting lug on the boiler with the lifting lugs that cannot be used for lifting can not be used for lifting. The length of the steel cord should be reasonably selected to avoid the scratching of the furnace due to the improper length of the steel cord. The boiler must be protected from any damage during handling and handling.

2. Reserves for maintenance space When installing boilers, ensure that there is sufficient maintenance space around the boiler.

3. Setting and precautions for the base and base of the gas steam boiler The boiler body must be installed on the basis of 100-150mm above the floor of the boiler room. It must be confirmed with the technical personnel of the boiler manufacturing company in advance and constructed according to the basic drawings. The anchor bolts must be reserved on the foundation. The foundation shall be capable of withstanding the maximum weight of the boiler and the amount of water it holds. When installing the base, you must first position it. After positioning, adjust to the same length of the two diagonals of the base, and then tighten all the fixing bolts. The installation of the base is carried out with reference to the reference line.

4, general precautions Be careful not to tilt and impact the boiler and accessories too much. No combustibles can be placed around the boiler. Do not use oil and water to smother the boiler. The boiler should normally be installed in a separate boiler room. The new gas-fired boiler room should not be connected to the house. The boiler room shall not be connected to Class A, Class B and Category C fire hazard rooms using flammable liquids. If connected to other production plants, the application firewall is separated.

5. The fire resistance grade and fire protection requirements of the boiler house building shall comply with the requirements of the Code for Fire Protection of Building Design and the Code for Fire Protection Design of High-rise Civil Buildings. The ground of the gas steam boiler room should be flat, non-flammable, no water accumulation, and the foundation load should meet the requirements. The power supply voltage of the gas steam boiler room should be stable to avoid causing the electrical components to burn out. If the voltage is unstable, it is recommended to install a voltage regulator. Ventilation equipment should be installed in the boiler room, and the boiler should be kept at room temperature below 50 °.

Further reading: Xuedong, male, Han nationality, born in August 1964, Tongling, Anhui Province, Communist Party members. Chinese Academy of Engineering, Director of the National Pressure Vessel and Pipeline Safety Engineering Research Center. He is the authority in the field of pressure vessels and piping of heat transfer, it specializes in high-temperature, high-pressure manufacturing issues at the state of the pressure vessel, and the Group's development has a strong bonding point. August 1986, Chemical Engineering and Equipment, Zhejiang University graduate. February 1993 - December 1995, a master's degree in chemical engineering Zhejiang University to study mechanical engineering. February 2001 - June 2004, in chemical engineering machinery Zhejiang University PhD. In November 2006, Ho Leung Ho Lee Foundation Science and Technology Innovation Award. June 19, 2017, in Anhui Province, Anhui Province Party Conference elected as delegates to attend the nineteen Party.

oil industry water tube boiler Related Information

Water tube boilers Products Commercial & Industrial

Water tube boilers. Warm water, hot water, saturated steam and superheated steam for commercial and industrial applications. Water tube boilers. Oil and gas fired water tube packaged boiler. With PLC system; Available in the output ranges from 10,000 to 45,000 kg/h, 7 to 29 MW;

Get a Quote

oil fired boiler in thermal power plant - Bing

Boiler (power generation) - Wikipedia. A boiler or steam generator is a device used to create steam by applying heat energy to water. These under-fired boilers were used in various forms throughout the 18th Century. Some were of The source of heat for a boiler is combustion of any of several fuels, such as wood, coal, oil, or natural gas.

Get a Quote

Henan Province Sitong Boiler Co., Ltd.

2020-2-1 · Gas Fired Water Tube Steam Boiler. learn more. Industrial Natural Gas Fired Steam Boiler. learn more. Gas Fired Thermic Oil Boiler. learn more. Small Capacity Gas Fired Boiler. learn more. Biomass Pellet Water Tube Steam Boiler. learn more. Solid Fuel Fired Steam Boiler. learn more. Coal Fired Thermal Oil Boiler. learn more. Industrial Electric

Get a Quote

steam boiler for palm oil industry in ghana - Bing

Coconut Shell Fired Steam Boiler Agent For Pharmaceutica. zhejiang tuff steam boilers - ricoma-stickmaschinen.de. Except hot oil boiler, oil gas fired steam boiler and biomass water tube steam boiler is also suitable for textile factories. tuff boiler in china in Food Industry. tuff boiler in china is very important for food processing industry, it can be used for drying, disinfect, curing

Get a Quote

The best biomass fired boiler manufacturer

China Biomass fired boiler have reached the world's advanced level. We are technical in gas oil boiler,coal boiler,CFB boiler and industrial autoclave.

Get a Quote

China Water Tube Boiler, Water Tube Boiler

China Water Tube Boiler manufacturers - Select 2020 high quality Water Tube Boiler products in best price from certified Chinese Boiler manufacturers, Oil Boiler suppliers, wholesalers and

Get a Quote

Henan Province Sitong Boiler Co., Ltd.

2020-2-1 · Gas Fired Water Tube Steam Boiler. learn more. Industrial Natural Gas Fired Steam Boiler. learn more. Gas Fired Thermic Oil Boiler. learn more. Small Capacity Gas Fired Boiler. learn more. Biomass Pellet Water Tube Steam Boiler. learn more. Solid Fuel Fired Steam Boiler. learn more. Coal Fired Thermal Oil Boiler. learn more. Industrial Electric

Get a Quote

China Oil Boiler, Oil Boiler Manufacturers, Suppliers

China Oil Boiler manufacturers - Select 2020 high quality Oil Boiler products in best price from certified Chinese Boiler manufacturers, Steel Boiler suppliers, wholesalers and factory on Made-in-China.com

Get a Quote

Oil and gas water tube boiler -- Boiler

2019-8-15 · The oil and gas water tube boiler is a szs series industrial boiler. The boiler adopts a double drum vertical arrangement. The boiler adopts a quick assembly structure, has the characteristics of compact structure and short installation period on the construction site.

Get a Quote

Industry Vacuum Water Tube Boiler Dealer

Industry Vacuum Boiler Dealer - mosaikbildnerei. Chemical Industry Vacuum Boiler Dealer. ZOZEN is one of the best modern boiler manufactures in China. chemical industry fuel vacuum water tube boiler dealer About Our company's main products include gas&oil-fired boiler, coal-fired boiler, biomass boiler, thermal fluid heater and other series with more

Get a Quote

industrial boiler,boiler in industry,use of boiler

2019-11-28 · Water is turned into hot water or steam by heating hot water boiler or steam boiler with fuels such as coal, oil, gas, biomass, which is the use of industrial boilers. The steam or hot water is then transported to the consumers via pipe systems. Loss of water must be compensated by treated fresh water to avoid corrosion.

Get a Quote

Alfa Laval - Aalborg OL

2020-4-11 · Aalborg OL is intended for steam or hot water production, the oil- or gas-fired Aalborg OL (formerly MISSION OL) is supplied as a vertical, two-drum cylindrical boiler. Its furnace, which is built with membrane walls and contains only little refractory material, is shaped to

Get a Quote

china boiler,thermal power plant,china - Just Industry

china boiler,boiler in china,thermal power plant,china steam boiler,steam turbine,absorption chiller,china gas boiler,china water boiler,china oil boiler,china biomass boiler,china wood boiler,china coal boiler,Qingdao Just Boiler co.,ltd

Get a Quote

What is Boiler ? Components & Application

What is a boiler? Boilers are defined as Boiler is a closed vessel in which water or other liquid is heated, steam or vapor is generated, steam is super-heated, or any combination thereof, under pressure or vacuum, for use external to itself, by the direct application of energy from the combustion of fuels, from electricity or nuclear energy.. The boiler is a primary part of global heating

Get a Quote

Industry Vacuum Water Tube Boiler Dealer

Industry Vacuum Boiler Dealer - mosaikbildnerei. Chemical Industry Vacuum Boiler Dealer. ZOZEN is one of the best modern boiler manufactures in China. chemical industry fuel vacuum water tube boiler dealer About Our company's main products include gas&oil-fired boiler, coal-fired boiler, biomass boiler, thermal fluid heater and other series with more

Get a Quote

Do You Want To Get An Exclusive Project Plan ?

7 * 24 * 365 endless service, click the button to provide you with professional and fast solutions at any time

Scroll to Top